Guilin Zhou

Professor

Supervisor of Master's Candidates

E-Mail:

Business Address:

新北区(科创园)

Contact Information:

dicpglzhou@ctbu.edu.cn

Visit:

Open time:..

The Last Update Time:..

Paper Publications

Current position: Home > Scientific Research > Paper Publications

CeCu composite oxide for chlorophenol effective removal by heterogeneous catalytic wet peroxide oxidation

Release time:2024-12-01
Hits:

Impact Factor:
4.223
DOI number:
10.1007/s11356-019-07042-5
Affiliation of Author(s):
重庆工商大学
Journal:
Environmental Science and Pollution Research
Funded by:
重庆市科技局,重庆工商大学
Key Words:
Catalytic wet peroxide oxidation (CWPO);4-Chlorophenol;2,4-Dichlorophenol;CeCu oxide catalyst;Solid solution;Waste water
Abstract:
CeCu solid solution oxide catalysts were prepared by the complex method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Brunauer–Emmett–Teller (BET), and X-ray photoelectron spectroscopy (XPS). And its activity in the catalytic wet peroxide oxidation (CWPO) of 4-chlorophenol (4-CP) and 2,4-dichlorophenol (2,4-DCP) in water was investigated. The results showed that the Cu2+ ions dissolved into the CeO2 lattice to form CeCu solid solution oxide with a coarse, interconnected, porous, and cotton-like morphology. The metal-oxygen bonds were weakened by the formation of solid solution in the CeCu oxide catalyst. This weakening facilitated the activation and decomposition of the H2O2 to form highly oxidative HO• species that can lead to significant chlorophenol mineralization. The formation of CeCu solid solution oxide can effectively inhibit the Cu ions to be leached from the used CeCu oxide catalysts, which can ensure the CeCu oxide catalysts to adapt to a wide pH range of 2.1–7.9 and exhibit good reusability. CWPO reaction of 4-CP and 2,4-DCP molecules on CeCu oxide catalysts conforms to the first-order kinetic equation: y = 6959.3x − 17.2 and y = 9725x − 25.4, respectively. And the reaction activation energies are 57.8 and 80.8 kJ/mol, respectively. The TOC removals of 4-CP and 2,4-DCP can exceed 88 and 82%, and the dechlorination rates of 4-CP and 2,4-DCP are higher than 95 and 99.5%, respectively.
First Author:
Hongmei Xie
Co-author:
Jia Zeng
Indexed by:
源刊论文
Correspondence Author:
Guilin Zhou
Discipline:
Engineering
Document Type:
Journal Article
Volume:
27
Issue:
1
Page Number:
846–860
Translation or Not:
no
Date of Publication:
2020-01-01
Included Journals:
SCI
Links to published journals:
https://doi.org/10.1007/s11356-019-07042-5